Styrobeck Plastics Logo
form_flow form_flow form_flow 100% recycled
Form - Flow
 

Typical Retaining wall design using form-flowTakes a load off retaining walls. Installation is fast and simple. Simply place the Form~Flow panel firmly against the waterproofing membrane and above the drainage pipe. Immediately after the tanking is completed. Ensure all exposed waterproofing membrane cover is protected. A nonsolvent based glue can be used to hold panels in place whilst installing. Backfill with granular drainage metal or freedraining backfill. Walls exceeding 5 metres will require double thickness of Form Flow at base to ensure adequate resistance to compression loads. Form Flow can be easily cut to shape at site to fit any retaining wall. When installed correctly Form~Flow will met the provisions of NZBC B1.31, B1.3.2 and B1.3.4 under the relevant conditions of B1.3.3 relating to structure. Durability meets performance requirements of NZBC Clause B2.3.1(a) for 50 years so long as the material is not subject to solvents or physical damage.

Form~Flow is made from a specific process using only recycled EPS components. Unlike normal EPS blocks the result is a porous material still offering protective properties associated with EPS products.


NOTE: Form~Flow panel will assist the drainage of the backfill. However, for stability, material of adequate strength and permeability must be used behind the Form~Flow panel; ideally a sand or gravel material. In some cases the excavated material may be suitable for use as a back fill. Where there is doubt about the suitability of the excavated material for use as back fill, technical advice must be sought.

 
 

GEOTECHNICAL APPRAISAL TEST RESULTS : FORM~FLOW Date: July 1998

 

Test Standard (if applicable)

Test Result

Test Data:
Constant Head Test Data (150mm diameter test specimens):

Property Density

ASTM D 1622-93: Standard Test Method for Apparent Density of Rigid Cellular Plastics

12.2kg/m3

Parameter

Specimen Condition

Uncompressed

Compressed

Compressive Strength

ASTIM D 1621-94: Standard test Strength Method for Compressive Properties of Rigid Cellular Plastics

26.8kPa

Head(mm)

240

290

Permeability

10.21/M2 at 240mm constant head Equivalent to sand (uncompressed) 7.41/M2 at 290mm and sand-gravel constant head (compressed)

Equivalent to sand and sand-gravel mixtures

Thickness(mm)

100

60

Creep

Refer to full Opus appraisal no.2002/01

 

Flow rate (litres/second per m2 )

10.2

7.4

Permittivity (second-1 )

0.04

0.03

 
 

Comments:

Test results indicate that the product is suitable for use as a protective barrier and drainage medium behind retaining walls. Where backfill other than free draining granular material is used, appropriate consideration to strength, expansion/shrinkage and drainage of the backfill material is required.

Max. Wall Height:

5 metres ~ 1 panel thick. 5M+ ~ 2 panel thickness required to provide adequate resistance to compression loads.

Chemical Resistance:

Resistant to most aqueous media, including dilute acids, alkalis, methanol, ethanol and silicon oils. Not resistant to hydrocarbon based solvents such as petrol, diesel, kerosene and white spirits. Do not place Form~Flow in contact with solvent which may damage it.

Durability:

50 years, Form~Flow will not rot and is highly resistant to mildew & bacteria.

Hazardous Building Materials:

Form~Flow does not present any health hazard during installation or in the serviceable life of the building in which it is used. Form~Flow does not irritate the skin and is nonallergenic.

Fire Hazard:

Form~Flow contains flame retardant conforming to AS1366,part 3-1992.

 
   
copyright Styrobeck plastics 2008